Amount netto: 0.00 zł
Amount brutto: 0.00 zł
Cable thermocouple
Type: TTE310, TTE311, TTE312

Applications
- Measuring range: -40 .. +400°C (depends on cable insulation)
- Plastic industry
- Light energy industry
- General industrial services
Features
- Single or double TC:
Type J (Fe-CuNi),
Type K (NiCr-NiAl),
Type N (NiCrSi-NiSi),
Type T (Cu-CuNi),
Type E (NiCr-CuNi) - Stainless Steel AISI321 / 1.4541
- Version with protection tube diameter Ø5 mm (TTE310), Ø6 mm (TTE311), Ø8 mm (TTE312)
Temperature range
Temperature range of the sensor depends on insulation of connection cable.
Temperature range | Possible diameters of protection tube | Cable insulation |
-10 .. +105°C | Ø6, Ø8 mm | PVC |
-40 .. +180°C | Ø6, Ø8 mm | silicone |
-40 .. +260°C | Ø5, Ø6, Ø8 mm | teflon® PFA |
-40 .. +400°C | Ø5, Ø6, Ø8 mm | fiberglass |
Description
Thermocouples TTE310, TTE311, TTE312 are designed for screw-fitting directly into machine body or parts. Adjustable spring force of sensor provides optimum measurement conditions in environment where vibrations appears.
Construction
The sensor consists of thermocouple cable, protection tube, spring and bayonet cap.
Insertion length, process connection, construction type, accuracy, cable insulation can be selected individually for the respective application.
ATEX, IECEx, EAC Ex versions 
Other versions