News

About us

Termoaparatura Wrocław is a manufacturer of industrial temperature sensors for all branches of industry. Wide range of sensors includes temperature sensors with connection heads, sheathed sensors and cable sensors. Selected types of sensors have been developed and certified as Exi – intrinsically safe and Exd – flameproof in accordance with ATEX Directive and IECEx scheme. On request, it is possible to design temperature sensors tailored to a specific application. At Termoaparatura we follow the rule of making the products of the highest quality based on the full use of modern technology.

Kalkulator
Unit converter

RTDs and TCs
characteristic calculator

Resistance thermometers

Thermocouples

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-200 °C - 850 °C

18,52 Ω - 390,48 Ω

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-60 °C - 250 °C

69,52 Ω - 289,16 Ω

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-210 °C - 1200 °C

-8,095 mV - 69,553 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1372 °C

-6,458 mV - 54,886 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1300 °C

-4,345 mV - 47,513 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1000 °C

-9,835 mV - 76,373 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 400 °C

-6,258 mV - 20,872 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,226 mV - 21,103 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,236 mV - 18,694 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

0°C - 1820 °C

-0,003 mV - 13,820 mV

Pomoc. Instrukcja użytkownika.

Unit
converter
RTDs and TCs
characteristic calculator