Choice variants available in e-shop
Your basket (0)
Item
product name
amount
Unit price (netto)

Amount netto: 0.00 zł

Amount brutto: 0.00 zł

HART® transparent repeater

Type: PR5106B

Configure and add to RFQ
Specify the various parameters of the product for enquiry
Product's properties:
Input
Output
Channels
Add to your enquiry
  • 3- / 5-port 3.75 kVAC galvanic isolation
  • Low response time
  • 2-wire supply > 17 V in Ex / I.S. area
  • 1- or 2-channel version
  • Universal supply by AC or DC

 

Application

 

  • Power supply and Ex / I.S. safety barrier with 2-way HART® communication for 2-wire transmitters installed in the hazardous area.
  • Ex / I.S. safety barrier with 2-way HART® communication for supplied current transmitters installed in the hazardous area.
  • Signal isolator with low response time on analog current signals from the hazardous area.

 

Technical characteristics

 

  • PR5106B primarily processes current signals of 4...20mA.
  • PR5106B is based on microprocessor technology for gain and offset. The analog signal is transmitted at a response time of less than 25 ms.
  • Inputs, outputs, and supply are floating and galvanically separated.
  • The output can be connected either as an active current transmitter or as a 2-wire transmitter.

 

Mounting / installation

 

  • Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without distance between neighboring units, up to 84 channels can be mounted per meter.
  • PR5106B is recommended as Ex / I.S. safety barrier for 5335D and 6335D.
  • Description
    • 3- / 5-port 3.75 kVAC galvanic isolation
    • Low response time
    • 2-wire supply > 17 V in Ex / I.S. area
    • 1- or 2-channel version
    • Universal supply by AC or DC

     

    Application

     

    • Power supply and Ex / I.S. safety barrier with 2-way HART® communication for 2-wire transmitters installed in the hazardous area.
    • Ex / I.S. safety barrier with 2-way HART® communication for supplied current transmitters installed in the hazardous area.
    • Signal isolator with low response time on analog current signals from the hazardous area.

     

    Technical characteristics

     

    • PR5106B primarily processes current signals of 4...20mA.
    • PR5106B is based on microprocessor technology for gain and offset. The analog signal is transmitted at a response time of less than 25 ms.
    • Inputs, outputs, and supply are floating and galvanically separated.
    • The output can be connected either as an active current transmitter or as a 2-wire transmitter.

     

    Mounting / installation

     

    • Mounted vertically or horizontally on a DIN rail. As the devices can be mounted without distance between neighboring units, up to 84 channels can be mounted per meter.
    • PR5106B is recommended as Ex / I.S. safety barrier for 5335D and 6335D.
  • Documents
Kalkulator
Unit converter

RTDs and TCs
characteristic calculator

Resistance thermometers

Thermocouples

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-200 °C - 850 °C

18,52 Ω - 390,48 Ω

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-60 °C - 250 °C

69,52 Ω - 289,16 Ω

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-210 °C - 1200 °C

-8,095 mV - 69,553 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1372 °C

-6,458 mV - 54,886 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1300 °C

-4,345 mV - 47,513 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1000 °C

-9,835 mV - 76,373 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 400 °C

-6,258 mV - 20,872 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,226 mV - 21,103 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,236 mV - 18,694 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

0°C - 1820 °C

-0,003 mV - 13,820 mV

Pomoc. Instrukcja użytkownika.

Unit
converter
RTDs and TCs