Choice variants available in e-shop
Your basket (0)
Item
product name
amount
Unit price (netto)

Amount netto: 0.00 zł

Amount brutto: 0.00 zł

Insulated thermocouple wire

Type: GHGH

Configure and add to RFQ
Specify the various parameters of the product for enquiry
Product's properties:
Construction
Type
No of conductors x cross section
Add to your enquiry
  • High quality product
  • Color marking according to IEC 584-3, optional ANSI/MC 96.1 (ASTM E230)
  • Available wires materials K, N

 

Most popular and inexpensive insulation material. Generally used for making simple thermocouples.

 

Parallel positioning of conductors in GH fiber glass insulation, each one of them. Outer sheath made of GH fiber glass braiding has oval shape. It is designed for work in dry areas with small mechanical load.

 

Working temperature

 

Insulation temperature resistance from -40oC up to +600oC.

 

 

Available versions

 

Insulation designation

No of conductors/

diameter

Outer dimension

Thermocouple type
Color marking according to IEC 584-3

K

J

T

N

E

GHGH

Special fiber glass

(-40..+600oC)

2 x 0.50 mm

1.5 x 2.4 mm

 

 

 

2 x 1.00 mm

1.8 x 3.1 mm

 

 

 

 

 

Minimum order quantity

 

There is no minimum quantity requirements for standard versions of insulated thermocouple wires. Insulated thermocouple wires which does not figure in catalog, there are NO at stock. In this case they are delivered for a special order and minimum quantity order is required.

 

Presented insulated thermocouple wires in catalog by special order codes meets DIN and IEC standards about thermoelecric voltage, tolerances and color marking.

  • Description
    • High quality product
    • Color marking according to IEC 584-3, optional ANSI/MC 96.1 (ASTM E230)
    • Available wires materials K, N

     

    Most popular and inexpensive insulation material. Generally used for making simple thermocouples.

     

    Parallel positioning of conductors in GH fiber glass insulation, each one of them. Outer sheath made of GH fiber glass braiding has oval shape. It is designed for work in dry areas with small mechanical load.

     

    Working temperature

     

    Insulation temperature resistance from -40oC up to +600oC.

     

     

    Available versions

     

    Insulation designation

    No of conductors/

    diameter

    Outer dimension

    Thermocouple type
    Color marking according to IEC 584-3

    K

    J

    T

    N

    E

    GHGH

    Special fiber glass

    (-40..+600oC)

    2 x 0.50 mm

    1.5 x 2.4 mm

     

     

     

    2 x 1.00 mm

    1.8 x 3.1 mm

     

     

     

     

     

    Minimum order quantity

     

    There is no minimum quantity requirements for standard versions of insulated thermocouple wires. Insulated thermocouple wires which does not figure in catalog, there are NO at stock. In this case they are delivered for a special order and minimum quantity order is required.

     

    Presented insulated thermocouple wires in catalog by special order codes meets DIN and IEC standards about thermoelecric voltage, tolerances and color marking.

  • Documents
Kalkulator
Unit converter

RTDs and TCs
characteristic calculator

Resistance thermometers

Thermocouples

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-200 °C - 850 °C

18,52 Ω - 390,48 Ω

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-60 °C - 250 °C

69,52 Ω - 289,16 Ω

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-210 °C - 1200 °C

-8,095 mV - 69,553 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1372 °C

-6,458 mV - 54,886 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1300 °C

-4,345 mV - 47,513 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1000 °C

-9,835 mV - 76,373 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 400 °C

-6,258 mV - 20,872 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,226 mV - 21,103 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,236 mV - 18,694 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

0°C - 1820 °C

-0,003 mV - 13,820 mV

Pomoc. Instrukcja użytkownika.

Unit
converter
RTDs and TCs
characteristic calculator