Intrinsically Safe Cable Thermocouple

Type: XI-TTE310, XI-TTE311, XI-TTE312

Configure and add to RFQ
Specify the various parameters of the product for enquiry
Product's properties:
Protection tube dia. D / Bayonet cap dia. d [mm]
Thermocouple type
Length L [mm]
Cable length Lp [mm]
Tolerance class
Cable insulation
Thread type
Add to your enquiry

ATEX Designation:

I M1 Ex ia I Ma
II 1/2G Ex ia IIC T.. Ga
II 1/2D Ex ia IIIC T.. Da

 

IECEx Designation:

I M1 Ex ia I Ma
Ex ia IIC T.. Ga
Ex ia IIIC T.. Da

 

EAC Ex Designation:

PO Ex ia I Ma X
0Ex ia IIC T..Ga X
0Ex ia IIIC T..Da X

Certificate:

FTZU 10 ATEX 0062X

 

 

 

 

IECEx FTZU 16.0015X

 

 

 

 

RU C-PL.MЮ62.B.04104

 

Applications

 

  • Measuring range: -40 .. +400°C (depends on cable insulation)
  • Plastic industry
  • Light energy industry
  • General industrial services
  • Installation in hazardous areas:
    Gases, vapors, mists (G): Zone 0, 1, 2
    Dusts (D): Zone 20, 21, 22
    Mines: M1

 

Features

 

  • Single or double TC:
    Type J (Fe-CuNi), 
    Type K (NiCr-NiAl), 
    Type N (NiCrSi-NiSi), 
    Type T (Cu-CuNi), 
    Type E (NiCr-CuNi)
  • Stainless Steel AISI321 / 1.4541
  • Version with protection tube diameter Ø5 mm (XI-TTE310), Ø6 mm (XI-TTE311), Ø8 mm (XI-TTE312)

 

Temperature range

 

Temperature range of the sensor depends on insulation of connection cable.

Temperature range Possible diameters of protection tube Cable insulation
-10 .. +105°C Ø6, Ø8 mm
PVC
-40 .. +180°C Ø6, Ø8 mm
silicone
-40 .. +260°C Ø5, Ø6, Ø8 mm
teflon® PFA
-40 .. +400°C Ø5, Ø6, Ø8 mm
fiberglass

 

Description

 

Thermocouples of this series are designed for screw-fitting directly into a socket, mainly in extruding molds. These thermocouples are suitable for solid media under moderate mechanical load and normal chemical conditions.

 

Construction

 

The sensor consists of thermocouple cable, protection tube, spring and bayonet cap.

 

Insertion length, process connection, construction type, accuracy, cable insulation can be selected individually for the respective application.

 

Other versions

 

This data sheet contains only small part of our supplies program of cable thermocouples. Upon the customer's request, other versions can also be delivered.
  • Description
  • ATEX Designation:

    I M1 Ex ia I Ma
    II 1/2G Ex ia IIC T.. Ga
    II 1/2D Ex ia IIIC T.. Da

     

    IECEx Designation:

    I M1 Ex ia I Ma
    Ex ia IIC T.. Ga
    Ex ia IIIC T.. Da

     

    EAC Ex Designation:

    PO Ex ia I Ma X
    0Ex ia IIC T..Ga X
    0Ex ia IIIC T..Da X

    Certificate:

    FTZU 10 ATEX 0062X

     

     

     

     

    IECEx FTZU 16.0015X

     

     

     

     

    RU C-PL.MЮ62.B.04104

     

    Applications

     

    • Measuring range: -40 .. +400°C (depends on cable insulation)
    • Plastic industry
    • Light energy industry
    • General industrial services
    • Installation in hazardous areas:
      Gases, vapors, mists (G): Zone 0, 1, 2
      Dusts (D): Zone 20, 21, 22
      Mines: M1

     

    Features

     

    • Single or double TC:
      Type J (Fe-CuNi), 
      Type K (NiCr-NiAl), 
      Type N (NiCrSi-NiSi), 
      Type T (Cu-CuNi), 
      Type E (NiCr-CuNi)
    • Stainless Steel AISI321 / 1.4541
    • Version with protection tube diameter Ø5 mm (XI-TTE310), Ø6 mm (XI-TTE311), Ø8 mm (XI-TTE312)

     

    Temperature range

     

    Temperature range of the sensor depends on insulation of connection cable.

    Temperature range Possible diameters of protection tube Cable insulation
    -10 .. +105°C Ø6, Ø8 mm
    PVC
    -40 .. +180°C Ø6, Ø8 mm
    silicone
    -40 .. +260°C Ø5, Ø6, Ø8 mm
    teflon® PFA
    -40 .. +400°C Ø5, Ø6, Ø8 mm
    fiberglass

     

    Description

     

    Thermocouples of this series are designed for screw-fitting directly into a socket, mainly in extruding molds. These thermocouples are suitable for solid media under moderate mechanical load and normal chemical conditions.

     

    Construction

     

    The sensor consists of thermocouple cable, protection tube, spring and bayonet cap.

     

    Insertion length, process connection, construction type, accuracy, cable insulation can be selected individually for the respective application.

     

    Other versions

     

    This data sheet contains only small part of our supplies program of cable thermocouples. Upon the customer's request, other versions can also be delivered.
  • Documents
Kalkulator
Unit converter

RTDs and TCs
characteristic calculator

Resistance thermometers

Thermocouples

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-200 °C - 850 °C

18,52 Ω - 390,48 Ω

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-60 °C - 250 °C

69,52 Ω - 289,16 Ω

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-210 °C - 1200 °C

-8,095 mV - 69,553 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1372 °C

-6,458 mV - 54,886 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1300 °C

-4,345 mV - 47,513 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1000 °C

-9,835 mV - 76,373 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 400 °C

-6,258 mV - 20,872 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,226 mV - 21,103 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,236 mV - 18,694 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

0°C - 1820 °C

-0,003 mV - 13,820 mV

Pomoc. Instrukcja użytkownika.

Unit
converter
RTDs and TCs
characteristic calculator