Choice variants available in e-shop
Your basket (0)
Item
product name
amount
Unit price (netto)

Amount netto: 0.00 zł

Amount brutto: 0.00 zł

Cable thermocouple

Type: TTE500

Configure and add to RFQ
Specify the various parameters of the product for enquiry
Product's properties:
Thermocouple type
Cross section
Length L [mm]
Cable length Lp [mm]
Tolerance class
Cable insulation
Add to your enquiry

Applications

 

  • Measuring range: -40 .. +200°C
  • Machinery industry
  • General industrial services

 

Features

 

  • Single TC:
    Type J (Fe-CuNi), 
    Type K (NiCr-NiAl), 
    Type N (NiCrSi-NiSi), 
    Type T (Cu-CuNi), 
    Type E (NiCr-CuNi)
  • Self-advesive teflon® tape

 

Temperature range

 

Temperature range: -50 .. +200°C

 

Available thermocouple cables

 

Designation Cross-section Outside dimensions
T 2 x 0.20 mm  (wire)
2 x 0.50 mm  (wire)
Ø0.5 mm
Ø0.9 mm
TT

2 x 0.13 mm   (wire)
2 x 0.20 mm   (wire)
2 x 0.22 mm2 (string)

0.6 x 1.0 mm
1.3 x 2.0 mm
1.5 x 2.8 mm

 

Construction

 

The sensor consists of thermocouple wire and teflon® self-advesive tape.

 

Type of thermocouple, length, accuracy, cable insulation can be selected individually for the respective application.

 

ATEX, IECEx, EAC Ex versions  Certyfikaty ATEX, IECEx, EAC Ex

 

Intrinsically safe designs are available for applications in hazardous areas. These models are provided with certificate for „intrinsically safe“ type of protection according to Directive 2014/34/UE (ATEX), IECEx scheme and EAC Ex TR-CU 012/2011 (Eurasian Economic Union).


Other versions

 

This data sheet contains only small part of our supplies program of cable thermocouples. Upon the customer's request, other versions can also be delivered.
  • Description
  • Applications

     

    • Measuring range: -40 .. +200°C
    • Machinery industry
    • General industrial services

     

    Features

     

    • Single TC:
      Type J (Fe-CuNi), 
      Type K (NiCr-NiAl), 
      Type N (NiCrSi-NiSi), 
      Type T (Cu-CuNi), 
      Type E (NiCr-CuNi)
    • Self-advesive teflon® tape

     

    Temperature range

     

    Temperature range: -50 .. +200°C

     

    Available thermocouple cables

     

    Designation Cross-section Outside dimensions
    T 2 x 0.20 mm  (wire)
    2 x 0.50 mm  (wire)
    Ø0.5 mm
    Ø0.9 mm
    TT

    2 x 0.13 mm   (wire)
    2 x 0.20 mm   (wire)
    2 x 0.22 mm2 (string)

    0.6 x 1.0 mm
    1.3 x 2.0 mm
    1.5 x 2.8 mm

     

    Construction

     

    The sensor consists of thermocouple wire and teflon® self-advesive tape.

     

    Type of thermocouple, length, accuracy, cable insulation can be selected individually for the respective application.

     

    ATEX, IECEx, EAC Ex versions  Certyfikaty ATEX, IECEx, EAC Ex

     

    Intrinsically safe designs are available for applications in hazardous areas. These models are provided with certificate for „intrinsically safe“ type of protection according to Directive 2014/34/UE (ATEX), IECEx scheme and EAC Ex TR-CU 012/2011 (Eurasian Economic Union).


    Other versions

     

    This data sheet contains only small part of our supplies program of cable thermocouples. Upon the customer's request, other versions can also be delivered.
  • Documents
Kalkulator
Unit converter

RTDs and TCs
characteristic calculator

Resistance thermometers

Thermocouples

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-200 °C - 850 °C

18,52 Ω - 390,48 Ω

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-60 °C - 250 °C

69,52 Ω - 289,16 Ω

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-210 °C - 1200 °C

-8,095 mV - 69,553 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1372 °C

-6,458 mV - 54,886 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1300 °C

-4,345 mV - 47,513 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1000 °C

-9,835 mV - 76,373 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 400 °C

-6,258 mV - 20,872 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,226 mV - 21,103 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,236 mV - 18,694 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

0°C - 1820 °C

-0,003 mV - 13,820 mV

Pomoc. Instrukcja użytkownika.

Unit
converter
RTDs and TCs
characteristic calculator