Thermocouple (TC) with exchangeable measuring insert

Type: TT438, TT440, TT441, TT442, TT443, TT444

Configure and add to RFQ
Specify the various parameters of the product for enquiry
Product's properties:
Version
Diameter of ceramic protection tube
Thermocouple type
Connection head closing type
Connection head type
Thermowell material
Length L [mm]
Tolerance class
Measuring range for transmitter output 4-20 mA
Temperature transmitter type
Add to your enquiry

Applications

 

  • Measuring range: 0 .. +1800°C
  • Blast furnaces, regenerating air heaters
  • Industrial heating installations, heat generation
  • Glass / porcelain / ceramics industry
  • Cement and brick production

 

Features

 

  • Standard protection tube material:
    Ceramic C799 ( 99.7% Al2O3 )
  • Temperature transmitter can be installed inside connection head of sensor
  • Gastight process connection


Description

 

The sensor consists of an exchangeable measuring insert, outer ceramic protective tube and aluminum connection head where mounting a temperature transmitter with 4-20 mA/HART® or Profibus®PA output signal is possible.

 

The measuring insert that is used makes an exchangeable part of the sensor which means that only the insert and not the whole sensor has to be disassembled in case of damage or for the purpose of periodical checking. Costs of the maintenance are reduced then.

 

Thermocouple length, diameter of ceramic tube, connection head as well as type and number of sensors, accuracy and method of connection can be selected individually for the respective application.

 

Temperature transmitter ( Option )


Transmitter is mounted inside the connection head of the sensor: directly on measuring inset or in the high cap of head.


 

The second method is advantageous as it allows changing standard measuring inset quickly without a need to disassemble the transmitter; it means reduction of time and costs of maintenance of the sensor and protecting wires against any damage possible. Mounting of two transmitters inside the connection head available upon request.

 

Example of sensor installation



Example of sensor installation

 

ATEX, EAC Ex versions  Certyfikaty ATEX, EAC Ex

 

Intrinsically safe and Flameproof designs are available for applications in hazardous areas. These models are provided with certificate for „intrinsically safe“ type of protection according to Directive 2014/34/UE (ATEX) and EAC Ex TR-CU 012/2011 (Eurasian Economic Union).


Other versions

 

This data sheet contains only small part of our supplies program of resistance thermometers with exchangeable measuring insert. Upon the customer's request, other versions can also be delivered.
  • Description
  • Applications

     

    • Measuring range: 0 .. +1800°C
    • Blast furnaces, regenerating air heaters
    • Industrial heating installations, heat generation
    • Glass / porcelain / ceramics industry
    • Cement and brick production

     

    Features

     

    • Standard protection tube material:
      Ceramic C799 ( 99.7% Al2O3 )
    • Temperature transmitter can be installed inside connection head of sensor
    • Gastight process connection


    Description

     

    The sensor consists of an exchangeable measuring insert, outer ceramic protective tube and aluminum connection head where mounting a temperature transmitter with 4-20 mA/HART® or Profibus®PA output signal is possible.

     

    The measuring insert that is used makes an exchangeable part of the sensor which means that only the insert and not the whole sensor has to be disassembled in case of damage or for the purpose of periodical checking. Costs of the maintenance are reduced then.

     

    Thermocouple length, diameter of ceramic tube, connection head as well as type and number of sensors, accuracy and method of connection can be selected individually for the respective application.

     

    Temperature transmitter ( Option )


    Transmitter is mounted inside the connection head of the sensor: directly on measuring inset or in the high cap of head.


     

    The second method is advantageous as it allows changing standard measuring inset quickly without a need to disassemble the transmitter; it means reduction of time and costs of maintenance of the sensor and protecting wires against any damage possible. Mounting of two transmitters inside the connection head available upon request.

     

    Example of sensor installation



    Example of sensor installation

     

    ATEX, EAC Ex versions  Certyfikaty ATEX, EAC Ex

     

    Intrinsically safe and Flameproof designs are available for applications in hazardous areas. These models are provided with certificate for „intrinsically safe“ type of protection according to Directive 2014/34/UE (ATEX) and EAC Ex TR-CU 012/2011 (Eurasian Economic Union).


    Other versions

     

    This data sheet contains only small part of our supplies program of resistance thermometers with exchangeable measuring insert. Upon the customer's request, other versions can also be delivered.
  • Documents
Kalkulator
Unit converter

RTDs and TCs
characteristic calculator

Resistance thermometers

Thermocouples

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-200 °C - 850 °C

18,52 Ω - 390,48 Ω

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-60 °C - 250 °C

69,52 Ω - 289,16 Ω

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-210 °C - 1200 °C

-8,095 mV - 69,553 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1372 °C

-6,458 mV - 54,886 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1300 °C

-4,345 mV - 47,513 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1000 °C

-9,835 mV - 76,373 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 400 °C

-6,258 mV - 20,872 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,226 mV - 21,103 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,236 mV - 18,694 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

0°C - 1820 °C

-0,003 mV - 13,820 mV

Pomoc. Instrukcja użytkownika.

Unit
converter
RTDs and TCs
characteristic calculator