Your basket (0)
Item
product name
amount
Unit price (netto)

Amount netto:0.00 zł

Amount brutto:0.00 zł

Thermocouples with connection head
The sensors with connection head have modular structure, which means that they consist of parts that can be selected depending on particular needs. These sensors consist of a measuring insert with terminal block, neck, protection tube and connection head.
Mineral insulated thermocouples
Mineral thermocouples are used for direct measurement of temperature in confined areas where there is a need for flexible sensors of a small diameter, high resistance to vibrations and shock and short response time to temperature change. MI sensors are made with a cable, connector or a connection head.
Cable thermocouples
Cable thermocouples are used for direct measurement of temperature in confined areas where there is a need for a small diameter, high resistance to vibrations and shock. Wide range of construction models makes them mostly common sensors on the market.

Thermocouples (TCs)

Thermocouples with connection head
The sensors with connection head have modular structure, which means that they consist of parts that can be selected depending on particular needs. These sensors consist of a measuring insert with terminal block, neck, protection tube and connection head.
Mineral insulated thermocouples
Mineral thermocouples are used for direct measurement of temperature in confined areas where there is a need for flexible sensors of a small diameter, high resistance to vibrations and shock and short response time to temperature change. MI sensors are made with a cable, connector or a connection head.
Cable thermocouples
Cable thermocouples are used for direct measurement of temperature in confined areas where there is a need for a small diameter, high resistance to vibrations and shock. Wide range of construction models makes them mostly common sensors on the market.

Sensors with connection head

Thermocouples with connection head (aluminium, plastic or stainless steel). Temperature transmitter can be installed inside connection head of sensor.

Sensors with thermocouple cable

Sensors with extension/thermocouple cable, relatively inexpensive solutions to meet requirements of most applications. Used mainly in low and medium temperature ranges.

Kalkulator
Unit converter

RTDs and TCs
characteristic calculator

Resistance thermometers

Thermocouples

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-200 °C - 850 °C

18,52 Ω - 390,48 Ω

Cold Junction Compensation = °C

Calculate value of resistance to temperature
(values according to ITS-90 scale)

R = Ω  T = 0 °C

Calculate value of temperature to resistance
(values according to ITS-90 scale)

T = °C R = 0 Ω

Limit values for the calculator

-60 °C - 250 °C

69,52 Ω - 289,16 Ω

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-210 °C - 1200 °C

-8,095 mV - 69,553 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1372 °C

-6,458 mV - 54,886 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1300 °C

-4,345 mV - 47,513 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 1000 °C

-9,835 mV - 76,373 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-270 °C - 400 °C

-6,258 mV - 20,872 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,226 mV - 21,103 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

-50 °C - 1768.1 °C

-0,236 mV - 18,694 mV

Cold Junction Compensation = °C

Calculate value of thermoelectric emf to temperature

E = mV T = 0 °C

Calculate value of temperature to thermoelectric emf

T = °C  E = 0 mV

Limit values for the calculator

0°C - 1820 °C

-0,003 mV - 13,820 mV

Pomoc. Instrukcja użytkownika.

Unit
converter
RTDs and TCs
characteristic calculator